News
News
solenoid valve Cv 2010-12-08
The flow I sent the vendor is in slpm, and the fluid is gas (don't ask me why the designer of this unit loves to use slpm instead of mass rate). the vendor came back with Cv value and when I looked at
Actuator:Sluice gate 2010-12-07
We are specifying 84" x 144" sluice gates in one of our projects and we expect very high torque and thrust required for the actuator to pull up the gate under a head of 40ft water. What type/brand of
PTFE Packing for Fugitive Emission control 2010-12-07
Can we use PTFE Gland packing in Fugitive Emission Control design (Globe Valves). I heard PTFE will fail during thermal cycle tests as prescribed in ISO 15848?
Mag Meter 2010-12-07
I spoke with Siemens today about their Magmeters they want us to use on our equipment.
He stated flat out that they care not at all about flow runs or pipe and fittings before or after their flow mete
Valve Class 2010-12-06
If a valve is supposed to be say Class 800, what does it mean? I am sure it is related to pressure and temperature but do not know the exact meaning.
Flashing Accross the Control Valve 2010-12-06
I am designing the piping system for my treater desanding system. the treater is operationg at about 80 psig and and i have 2" sch. 160 line coming out of treater going into an atmospheric tank.
liquid HCL isolating valves 2010-12-06
We have been facing serious problems in two areas of our plant. One is in liquid HCL isolating valves, we have more than 50 valves on dry HCL service at very low temperature but every now and then, we
Valves inspection ANSI B16.34 and API 6D 2010-12-03
I am looking for the tests and inspection that are commonly specified when purchasing ball, gate, globe etc valves for any service (water, steam and other). Reviewing ANSI B16.34 it seems to require o