Questions on a Homestead 126 Eccentric Plug Valve 2010-11-04
I have a Homestead 126 Eccentric Plug Valve with Neoprene plug coating and seals and memory stop handle trim. I have this valve installed on the pump discharge of a condensate heating system.
Closing valve 2010-11-04
I have a problem that I though you could help me with. :)I need some kind of device that closes on high pressure. What are the options?
Subsea Choke Erosion 2010-11-04
I've been tasked with determining whether our subsea choke valves are at risk due to erosion. The design data is:flow of water = 4000 m3/day (SG = 0.96)flow of oil = 2000 m3/day (SG = 0.87)flow of NG
Socket welded valves 2010-11-03
I am having a requirement for two nos of 1" Class 150- C.S. gate valves. Being socket welded valves, i had specified them as class 800. However I am having two different pipe wall thickness for 1" pip
Why does gland packing blowout? 2010-11-03
We just experienced a gland packing blowout on an 8" 600# gate valve in a 600psi steam service. The valve had been closed for several years. As the operator was opening it, the packing material extrud
Actuated Valve Dimension: Face to Face 2010-11-03
Can more knowledgable persons please explain because I am not very familiar with details of valves and its dimensions.For pneumatic actuated valves, would the face to face dimension be the same as a m
Duo Check Valves. How Leak test it? 2010-11-03
We designing a bildge-ballast system for a ship River and selected valves duo check for suction lines (Low weigth). Crane Duo Check valves were select in ASTM A395 with metal seat and interior stain
Fast opening, high pressure valve 2010-11-03